Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 09/10/2002 |
POOL/SPA FINAL/BARRIER |
|
Approved |
IVRS - Inspection 0000* |
| 09/05/2002 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED VERIFICATION OF 8030, 8035 INSPECTION APPROVALS 2) 48" RADIUS TOP OF ENCLOSURE EXTERIOR, NO CLIMABLE AREAS ALLOWED 3) DOOR INTO WOOD STORAGE IN ENCLOSURE ALLOWS ACCESS TO EXTERIOR OF ENCLOSURE, ALL DOORS/GATES TO BE SELF CLOSING. PLAN DOES NOT SHOW WOOD SHED 4) PERMIT FOR PORTABLE SPA? 5) NO OPENINGS LARGER THAN 4" UNDER METAL FENCE |