Inspection History Details
Inspection Status: Denied
Inspection History: GRADING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2003 | GRADING - FINAL | Denied | 1. ROOF DRAINAGE MUST FLOW BELOW SIDEWALKS AND PEDESTRIAN WALKWAYS PER C.O.T. DEVELOPMENT STANDARD NO. 2.08. ALSO NEEDS SPLASH BLOCKS AND EROSION PROTECTION. 2. RETENTION/DETENTION BASIN B IS NOT CONSTRUCTED PER PLAN SPECIFICATIONS. PROVIDE 45' WEIR. 3. PROVIDE DETAILS FOR CURB OPENINGS. 4. PROVIDE BOLLARDS AT CURB OPENINGS. 5. PROVIDE SIDEWALK TO EXISTING RIGHT OF WAY ON 22ND STREET. 6. PROVIDE BIKE RACK, BIKE RACK SIGN AND DO NOT ENTER SIGN. 7. PROVIDE RAMPS AT SOUTHEAST SIDE OF BLDG.1. 8. PROVIDE CONCRETE PAD FOR GARBAGE DUMPSTER. 9. PROVIDE 5' CMU SCREEN WALL AT SOUTHEAST CORNER. 10. PROVIDE DIMENSIONS AND FINISHED ELEVATIONS FOR RETENTION BASIN "A". INLET RIP RAP NEEDS TO MEET BOTTOM OF BASIN |