03/04/2003 GRADING - FINAL Approved
02/05/2003 GRADING - FINAL Denied 1) ADDRESS STANDING WATER IN RETENTION BASINS
2) VERIFY 4:1 SLOPES IN RETENTION BASINS.
3) PROVIDE DRAWINGS AND CALCULATIONS FOR DIMINISHED SIZE FOR RETENTION BASIN #1
4) TRIM DAMAGED PIPE ENDS BETWEEN RETENTION BASINS 2 & 3.
5) PROVIDE (3) ROCK RIP RAP SPILLWAYS AND APRONS PER KEYNOTE 24, PAGE C2.02.
6) PROVIDE INFORMATION REGARDING OFF-SITE DRAINAGE/STORMWATER RUN-ON FOR SOUTHWEST CORNER OF PROJECT WHERE 6' WROUGHT IRON FENCE WAS REPLACED WITH A 6' CMU WALL.