Case: T01VL02424

Parcel: 117042600


Addresses:

242 E 5TH ST

Inspection Status: Not ready for Inspection

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
10/04/2001 FOLLOW UP CODE VIOLATION Not ready for Inspection on 10-3-01...
INSPECTION SHOWED SOME IMPROVEMENTS, VERY MINOR...PROPERTY OWNER ON SITE AT LAST INSPECTION, STATED HE WANTED TO RE-RENT BASEMENT UNIT AGAIN, HE WAS ADVISED TO GET APPROVAL FROM ZONING FIRST AND WOULD NOT BE ABLE TO RE-RENT UNTIL ALL REQUIREMENTS ARE MET BY ALL . INSPECTIONS RESULTS AS FOLLOWING.
UNIT -1
UNABLE TO INSPECT, NEW SMOKE DECT. ON FRONT STEP TO BE INSTALLED...
UNIT -2
ALL WATER LEAKS REPAIRED, SMOKE DECT. INSTALLED...
UNIT- 3
GAS LINES HAVE BEEN CAPPED AND NEW GAS SHUT-OFFS INSTALLED , SMOKE DECT...OK, COOLER STAND REPAIRED AND NEW ELECT. INSTALLED PROPERLY.
UNIT-4
SECURED-----BASEMENT UNIT.

UNIT-5 NOT INSPECTED-NOT HOME...

NO PERMITS FOUND TO DATE- JUST ELECT.

NO OTHER REPAIRS MADE TO UNITS.........CASE HAS BEEN ABATED.
08/23/2001 FOLLOW UP CODE VIOLATION Correction Required SUMMARY OF VIOLATIONS RE SABER N&O.

1) UHC 301: STRUCTURAL = THE MAIN STRUCTURE HAS BEEN CONVERTED FROM A SINGLE FAMILY RESIDENCE INTO MULTI-FAMILY UNITS WITHOUT HAVING OBTAINED REQUIRED PERMITS AND RELATED INSPECTIONS.
2) UHC 301: ELECTRICAL= THE MAIN HOUSE HAS EXTENSIVE ELECTRICAL WORK AND CIRCUITS ADDED IN ORDER TO SERVICE THE UNITS WHEN THE MAIN HOUSE WAS DIVIDED. THE MAIN SERVICE HAS BEEN UPGRADED WITHOUT PERMITS, INSPECTIONS AND CLEARANCES.
3) UHC 301: PLUMBING= GAS, WATER,SANITATION LINES AND A WATER HEATER HAVE BEEN ADDED, MODIFIED AND EXTENDED IN ORDER TO SERVICE THE ADDITIONAL UNITS. UNIT 3 HAS AN UNCAPPED GAS LINE.
4) UHC 301: REAR STRUCTURE= THE REAR PERMITTED STORAGE STRUCTURE HAS BEEN CONVERTED TO A DWELLING UNIT WITH PLUMBING, ELECTRICAL AND STRUCTUAL WORK WITHOUT OBTAINING REQUIRED PERMITS AND RELATED INSPECTIONS.
5) UHC 601.2: WEATHER PROTECTION= UNITS 1, 3,4,5 CONTAIN WINDOWS AND DOORS LACKIING WEATHER SEALS. UNITS 3 & 4 HAVE ROOF LEAKS AND HOLES IN THE WALLS PENETRATING TO THE EXTERIOR.
6) UHC 701.1: HEATING= UNITS 2,3,4,5 LACK PROPER HEATING FACILITIES.
7) UHC 701.2: COOLING= UNIT1 HAS COOLER WIRING INSTALLED IMPROPERLY. UNIT 3 HAS AN IMPROPERLY INSTALLED AND DETERIORATED EVAPORATIVE COOLER CAUSING IT TO FALL.
8) UHC 701.3 HAZARDOUS ELECTRICAL= THE MAIN SERVICE IS CONNECTED THROUGH THE USE OF JUMPER WIRES WHICH IS NOT AN APPROVED METHOD. THE ELECTRICAL SYSTEM FOR THE STRUCTURE IS OVERLOADED DUE THE EXTENSIVE USE OF EXTENSION CORDS, THE USE OF GENERAL USE RECEIPTICLES TO RUN EVAPORATIVE COOLERS AND THE NUMBER OF UNITS. UNIT 1 HAS ADDED CIRCUITS ON THE OUTSIDE OF THE WALL WITH ELECTRICAL WIRES NOT IN CONDUIT. UNIT 2, CONTAINS OPEN GROUNDS, EXTENSION CORDS USED TO EXTEND CIRCUITS DUE TO LACK OF RECEPTICLES. SOME OF THE RECEPTICLES ARE NON FUNCTIONING. THE COOLER SUPPLY CORD WAS SPLICED AND PLUGGED INTO THE GENERAL RECEPTICLE CIRCUIT. UNIT 3, CONTAINS BARE ELECTRICAL WIRES OUTSIDE THE EXTERIOR DOOR AND TO THE EVAPORATIVE COOLER. THE PORCH LIGHT IS IMPROPERLY WIRED. UNIT 4, CONTAINS OUTLETS WITH OPEN GROUND, AND HAZARDOUS USE OF EXTENSION CORDS TO EXTEND CIRCUITS DUE TO LACK OF RECEPTICLES. UNIT 5, HAS AN OVERHEAD LIGHT FIXTURE WITH EXPOSED WIRES. LIVING ROOM RECEPTICLES ARE NOT OPERABLE.
9) UHC 801: EXITS= UNIT 2, LACKS PROPER EXITING FROM THE BEDROOM DUE TO AN EVAPORATIVE COOLER INSTALLED IN THE ESCAPE WINDOW. THE SECONDARY WINDOW DOES NOT MEET CODE. UNIT 3, HAS A BEDROOM THAT HAS EXITING INTO A SMALL HALL WAY FROM THE BASEMENT RESULTING FROM THE DIVISION OF THE MAIN STRUCTURE INTO UNITS. UNIT 5, IS A BASEMENT CONVERTED INTO A LIVING UNIT. THE WINDOWS DO NOT MEET CODE FOR EXITING. ADDITIONALLY, THE INSTALLATION OF THE WINDOW COOLER COMPLETLY ENCLOSES THE UNIT WITH NO EMERGENCY ESCAPE.
10) UHC 901: SMOKE DETECTORS= UNITS 1,2,3,4,5,6 LACK SMOKE DETECTORS.



ORDER

YOU HAVE 1) 5-DAYS IN WHICH TO COMPLETE PERMITS AND INSPECTIONS UTILIZING A LICENSED ELECTRICAL CONTRACTOR TO CORRECT THE DEFICIENCIES ASSOCIATED WITH THE MAIN SERVICE PANEL.
AND
YOU HAVE 2) 30-DAYS IN WHICH TO COMPLY WITH CITY PERMITTING REQUIREMENTS ASSOCIATED WITH THE CONVERSION OF A SINGLE FAMILY RESIDENCE AND STORAGE SHED TO A MULTI FAMILY UNITS. FAILURE TO COMPLY WITH THE FIRST REQUIRMENTS WILL RESULT IN THE DISCONNECTION OF THE POWER SUPPLY TO ALL THE EXISTING STRUCTURES AND UNITS.