Inspection Status: Closed
Inspection History: INITIAL CODE VIOLATION
| Date |
Description |
Inspector |
Results |
Comments |
| 08/22/2001 |
INITIAL CODE VIOLATION |
|
Closed |
|
| 08/14/2001 |
INITIAL CODE VIOLATION |
|
Violation |
IMPROPER OVERCURRENT PROTECTION AT PEDESTAL TO POWE OUTLET RECEPTACLE FOR THE MOBILE HOME LIFE LINE. OK. NEW WIRING TO NEW POST LAMP. NO PERMITS/INSPECTION WIRING NOT APPROVED FOR UNDERGROUND USE. IMPROPER WIRING METHODS EG. USING PLUMBING FITTINGS IMPROPER RACEWAY TERMINATION ETC. |
| 08/14/2001 |
INITIAL CODE VIOLATION |
|
Approved |
RE-SUBMIT OF INITIAL NOTICE OF VIOLATION ORGINAL LOST TO THEFT OF CITY VEHICLE ITEMS OUTLINED IN NOTICE OF VIOLATION DATED REPAIRED/ABATED IMPROPER OVER CURRENT PROTECTION: BREAKER CHANGED TO 50 AMP 2 POLE OK 2.) POST LAMP WIRING WRONG MATERIAL, NO INSPECTION REMOVED OK 3.) IMPROPER WIRING METHODS USING PLUMBING FITTINGS AND IMPROPER CONDUIT TERMINATION ABATED OK. |