Case: T01VL02213

Parcel: 120071560


Addresses:

225 W LINCOLN ST


Inspection Status: Correction Required

Inspection History: FOLLOW UP CODE VIOLATION

Case Number - T01VL02213

Inspection Description - FOLLOW UP CODE VIOLATION

Inspection Status - Correction Required

Date Description Inspector Results Comments
09/10/2001 FOLLOW UP CODE VIOLATION Correction Required FOLLOW UP INSPECTION 09/10/01

CONDUCTED FOLLOW UP INSPECTION FOR SABER ACTION. INSPECTED ALL 3-UNITS BY RICK SALDATE (DSD) AND GLENN (TFD).

1) REAR UNIT: WAS VACANT WITH COMPUTER SHOWING NO PERMITS RE ADDITION AND PORCH. OWNER STATED PREVIOUS INSPECTOR-II PASSED STRUCTURE AND POINTED OUT ISSUES SUCH AS HEATER AND BATHROOM DOOR. RICK SALDATE POINTED OUT ADDITION CONTAINING HAZARDOUS ELECTRICAL WIRING WHICH WOULD NEVER HAD BEEN PASSED BY THE PREVIOUS SUPERVISOR. OWNER ADMITTED THAT THAT ADDITON WAS ADDED AFTERWARDS. OTHER ISSUES INCLUDING GAS PIPING HAVE DETERIORATED DUE TO LACK OF MAINTENANCE. GAS PIPING INSIDE AND OUTSIDE WERE FOUND LACKING ANCHORING, WATER HEATER, COOLER AND OTHER ELECTRICAL CIRCUITS HAVE EITHER DETERIORATED OR HAD BEEN MODIFIED TO THE POINT OF THE INABILITY TO DETERMINE WHAT WAS ORIGINALLY PERMITTED.

2) FRONT WEST UNIT: HAS NOT BEEN ADDRESSED OTHER THAN CORRECTIONS REQUIRED IMMEDIATLY FROM INITIAL INSPECTION. LIGHT IN SHOWER STALL WHICH WAS ORDERED DESCONNECTED BY INSPECTOR RICHARD VIDAL ON INITIAL INSPECTION WAS FOUND RE-CONNECTED AND IN A HAZARDOUS CONDITION. RICK HAD OWNER DISCONNECT ONCE MORE. NO OTHER ISSUES RE N & O HAVE BEEN CORRECTED. ADDTION TO REAR HAS DETERIORATED FURTHER IN THAT WINDOWS IN BEDROOM WERE FOUND BROKEN OUT, BLOCK ABOVE REAR DOOR SHOWS ADDTIONAL MOVEMENT AND ROOF APPEARS TO HAVE UPLIFTED SOMWHAT. OWNER WAS IN PROCESS OF EVICTING TENANTS WITH BELONGINGS PLACED IN FRONT YARD.

3) FRONT EAST UNIT: TENANTS WERE NOT HOME BUT OWNER ALLOWED ESCORTED ENTRY. COMPUTER RECORDS AGAIN SHOW NO PERMIT ACTIVITY AND WHEN QUESTIONED AS TO THE STATUS, THE OWNER REPLIED THAT HE BELIEVED THAT THE ADDTIONS WERE PASSED IN THIS UNIT DUE TO PREVIOUS MIN-HOUSING INSPECTIONS BY THE PRIOR INSPECTOR-II OF DSD. RICK SALDATE EXPLAINED THAT FRONT PORCH WAS NOT PRESENT AT THAT TIME AND THAT AN OPEN PERMIT WAS ISSUED RE THE REAR ADDTIONS. OUR RECORDS INDICATE THAT THE OWNER THEN ALLOWED THE PERMITS TO EXPIRE WHILE CONTINUING TO BUILD WITH NO INSPECTIONS TO VERIFY NOW COVERED WORK. IT WAS THEN EXPLAINED THAT THE PLANS PREVIOULSY SUBMITTED DID NOT MATCH THE STRUCTURE. THE STRUCTURE LACKS A PARAPET WALL AND SHOULD NOT CONTAIN WINDOWS ON THE EAST SIDE. ALSO PLANS SHOW THE FRONT UNITS AS ONE HOUSE AND NOT THE CURRENT TWO UNITS. NO CORRECTIONS WERE FOUND IN THE UNIT.
08/21/2001 FOLLOW UP CODE VIOLATION Violation CERTIFIED MAIL RETURNED SIGNED F/U ON 09-07-01
08/15/2001 FOLLOW UP CODE VIOLATION Violation HAND DELIVERED AND SENT CERTIFIED.
07/24/2001 FOLLOW UP CODE VIOLATION Correction Required Follow up re immediate hazards:
Richard Vidal met owner on site after initial inspection to address hazardous electrical connections located in front units. Cooler connection in front, west unit and open conductor on front, east unit in kitchen window area. Owner agreed to address that day.