Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T01VL02178

Parcel: 137291030


Addresses:

1898 W ACORN WY

Inspection Status: Correction Required

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
07/19/2001 INITIAL CODE VIOLATION Correction Required HAS A MASONRY WALL BEING BUILT AND LACKING REBAR VERTICALS EVERY 4' O.C. BUT HAS DURA WIRE SUPPORTS EVERY OTHER COURSE. PUSHED AND PULLED ON WALL AND HAD NO MOVEMENT. HAS 2'-6" OF RETAINING OF FILL AND WALL IS GOING NO HIGHER. RETAINING PORTION IS NOT GROUTED. HAS TALK TO ZONING DOUG AND REYES ALVAYO FROM BUILDING ABOUT WALL. I WILL CHECK WITH EXAMINER AND GET BACK TO WONERS. F/U 30 DAYS ON 08-20-01