Permit: T01PL02582

Parcel: 117141280


Addresses:

318 S CONVENT AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T01PL02582

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
01/10/2002 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*ALL. CORRECTIONS MADE OK 2.) PIPING INSTALLED PER APPROVED PLAN. 3.) OK FOR GAS 4.) UCC LEFT AT METER 5.) GAS FOR ONE ROOF TOP UNIT.
01/08/2002 PLUMBING - GAS PRESSURE TEST Denied 1.) PLEASE USE CORRECT GUAGE, PRESSURE TEST OF 10# OR LESS REQUIRE A GUAGE WITH TENTH POUND INCREMENTS TEN TO ONE HUNDRED POUNDS REQUIRE ONE POUND INCREMENTS 2.) THIS IS A COMMERCIAL JOB AND REQUIRES AN APPROVED PLAN. IE ISOMETRIC DRAWING SHOWING DEVELOPED LENGTH AND TOTAL BTU CONSUMPTION.