Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01PL02557

Parcel: 129062160


Addresses:

2734 E 20TH ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
12/31/2001 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*1.) ABS BLDG SEWER FROM HOUSE TO HCS CONNECTION OK WATER TEST FROM LOWEST TO HIGHEST POINT OK 2.) OK TO BACKFILL 3.) WILL SEE: SEPTIC TANK FILLED WITH DIRT FINAL CONNECTIONS AT WASHER.
12/26/2001 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*1.) BLDG REQUIRES 2% PITCH 2.) WATER TEST FROM LOWEST TO HIGHEST POINT OF SEWER 3.) MAKE ALL SEWER CONNECTIONS. 4.) PUMP AND BREAK SEPTIC TANK HAVE SOILS AVAILABLE.
12/26/2001 PLUMBING - SEWER HCS CONNECT Denied 1.) BLDG SEWER REQUIRES 2% PITCH. 2.) WATER TEST FROM LOWEST TO HIGHEST POINT OF SEWER. 3.) MAKE ALL SEWER CONNECTIONS. 4.) PUMP AND BREAK SEPTIC TANK HAVE SOILS AVAILABLE.