Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) MUST REMOVE UNION IN LINE AND REPLACE WITH RIGHT & LEFT HAND NIPPLE OR PROVIDE A AGA OR CSA APPROVED SHUT OFF VALVE BEFORE THE UNION 2.) RE TEST SYSTEM 10LBS MIN. 3.) MUST SCREW DOWN FLU VENT @ WATER HTR ON VENT CONNECTOR AND ALL FLU VENT JOINTS WITH (3) SHEET METAL SCREWS PER JOINTS. |
| 01/11/2002 |
PLUMBING - FINAL |
|
Approved |
1.) RETURN VISIT 2.) GAS PRESSURE TEST IS OK 3.) GAS SHUT SHUT OFF VALVES OK 4.) WATER HTR FLU VENT OK. |
| 12/28/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 12/18/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* |