Permit: T01PL02528

Parcel: 128110990


Addresses:

5059 E TIMROD ST

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/11/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST REMOVE UNION IN LINE AND REPLACE WITH RIGHT & LEFT HAND NIPPLE OR PROVIDE A AGA OR CSA APPROVED SHUT OFF VALVE BEFORE THE UNION 2.) RE TEST SYSTEM 10LBS MIN. 3.) MUST SCREW DOWN FLU VENT @ WATER HTR ON VENT CONNECTOR AND ALL FLU VENT JOINTS WITH (3) SHEET METAL SCREWS PER JOINTS.
01/11/2002 PLUMBING - FINAL Approved 1.) RETURN VISIT 2.) GAS PRESSURE TEST IS OK 3.) GAS SHUT SHUT OFF VALVES OK 4.) WATER HTR FLU VENT OK.
12/28/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*
12/18/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*