Permit: T01PL02525

Parcel: 119033490


Addresses:

535 W 42ND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/17/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
10/14/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*
10/03/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SYSTEM MUST HOLD A MINIMUM OF 10# AIR TEST.
05/09/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
01/30/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SEE NOTE #2 FROM 01/09/02 THIS MEANS YOU MUST INSTALL TWO LOUVRES IN THE ENCLOSURE DOOR. ONE TO BE WITHIN THE UPPER TWELVE INCHES OF THE ENCLOSING; THE OTHER WITHIN THE LOWER TWELVE INCHES OF THE ENCLOSURE.
01/09/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*
12/18/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) A FLEX CONNECTOR MAY NOT PASS THROUGH A WALL OR A PARTITION. HARD PIPE INTO THE ENCLOUSURE AND RETEST TO 10# 2.) EXTEND T & P RELIEF DRAIN TO WITHIN 6" AFF 3.) FLEX CONNECTOR FOR WATER HEATER EXCEEDS ALLOWABLE LENGTH. 4.) STOVE OK FLEX AND VALVE OK.