Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 10/17/2002 |
PLUMBING - GAS RECONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 10/14/2002 |
PLUMBING - GAS RECONNECT |
|
Denied |
IVRS - Inspection 0999*1.) WATER HTR FLU VENT MUST BE 5'-0' MIN. 2.) WATER HTR FLU VENT REQUIRES A FLASHING ON ROOF 3.) MUST HAVE MIN 1' CLEARANCE AROUND FLU VENT FROM COMBUSTIONABLE MATERIAL 4.) MUST PROVIDE AGA OR CSA APPROVED SHUT OFF VALVES FOR RANGE & WATER HTR. 5.) MUST SCREW DOWN FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT 6.) PROVIDE AIR TEST 10LBS MIN. |
| 10/03/2002 |
PLUMBING - GAS RECONNECT |
|
Denied |
IVRS - Inspection 0999* |
| 05/08/2002 |
PLUMBING - GAS RECONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*TEST DOWN PLEASE PROVIDE 10LBS TEST ON COMPLETE SYSTEM NO BODY HOME. |
| 01/30/2002 |
PLUMBING - GAS RECONNECT |
|
Denied |
IVRS - Inspection 0999* |
| 01/09/2002 |
PLUMBING - GAS RECONNECT |
|
Denied |
IVRS - Inspection 0999*1.) T & P RELIEF DRAIN MAY NOT BE PVC USE APPROVED MATERIALS. 2.) NO COMBUSTION RELIEF IN WATER HEATER ENCLOSURE. |
| 12/18/2001 |
PLUMBING - GAS RECONNECT |
|
Denied |
IVRS - Inspection 0999* |