Permit: T01PL02493

Parcel: 136173040


Addresses:

3360 S MORMON DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/13/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
12/11/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) REMOVE UNION, USE RIGHT LEFT NIPPLE AND COUPLING ON SUPPLY LINE TO FURNACE.2.) REMOVE AND CAP AT MAIN THE ABANDONED GAS PIPE SERVICING THE OLD DRYER (NO LONGER THERE) 3.) NO T & P RELIEF DRAIN PIPE. VERIFY OPERATION OF VALVE, BEFORE INSTALLING NEW DRAIN. 4.) INSTALL SHUT OFF VALVE AT COLD WATER INLET TO WATER HEATER. 5.) POORLY CONNECTED FLUE PIPING IS ALLOWING RAIN WATER TO SATURATE TOP OF WATER HEATER.