Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/03/2002 |
PLUMBING - GAS PRESS TEST FNL |
|
Approved |
IVRS - Inspection 0000*1.) FURANCE FLU VENT & GAS SHUT OFF VALVE IS OK 2.) RANGE SHUT OFF VALVE IS OK 3.) GAS PRESSURE TEST IS OK 4.) U.C.C. HAS BEEN PLACED @ METER LOCATION. |
| 12/31/2001 |
PLUMBING - GAS PRESS TEST FNL |
|
Denied |
IVRS - Inspection 0999*1.) MUST HARD PIPE GAS LINE OUTSIDE OF FURNACE HOUSINS THEN CONNECT FLEX LINE. 2.) MUST PROVIDE AGA CSA APPROVED GAS SHUT OFF VALVES ON ALL APPLIANCES 3.) RE TEST SYSTEM. |