Permit: T01PL02410

Parcel: 129133970


Addresses:

1038 E 35TH ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/27/2001 PLUMBING - INTERMEDIATE Approved
12/24/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
12/06/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) GUAGE ON ZERO-MUST HOLD AT LEAST 10# FOR 15 MIN. 2.) WHERE PIPING MEETS, CONNECTION TO BE MADE WITH RIGHT LEFT NIPPLE AND COUPLING. 3.) UNIONS MAY BE USED IN EXPOSED EXTERIOR LOCATIONS, AND AS AN APPLIANCE CONNECTOR, WHEN IMMEDIATELY PRECEEDED BY AN APPROVED SHUT OFF VALVE. 4.) ALL VALVES TO BE AGA OR CSA APPROVED.