Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/10/2001 |
PLUMBING - GAS RECONNECT |
|
Approved |
IVRS - Inspection 0000*TEST OK ON COMPLETE SYSTEM PLEASE CALL FOR YOUR MECH INSP. LAST INSP ON JOB PLEASE PROVIDE GAS CARD. |
| 11/20/2001 |
PLUMBING - GAS RECONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) CODE VIOLATION ON RELIEF LINE CROSS CONNECTION TO WASTE NOT TO CODE 2.) CODE VIOLATION ON FURNACE FLEX THROU WALL OF FURNACE A HAS FURNACE BEEN INSPECTED AT TIME OF INSTALLATION. CALL YOUR INSTALLER. FOR PERMIT # OR HAVE PAPER WORK ON JOB AT TIME OF NEXT INSP. B IF NO PAPER WORK PROVIDE PERMIT FOR FURNACE & CALL FOR INSP. ALSO C.) CODE VIOLATION ON VENT FOR FURNACE PROVIDE PROPER CLEARENCE ON VENT. D.) WILL NEED MECH INSP TO INSP FOR PROPER COMBUSTION & RELIEF AIR 3.) TEST TO REMAIN ON FOR NEXT INSP. RENT UNIT REQUIRES LICENSE CONTRACTOR. |