Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/24/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) MUST USE ENTIRE FLASHING ON ARE ROOF PENETRATIONS.2.) MUST USE AGA GAS SHUT OFF VALVE FOR DRYER. 3.) MUST CONNECT LOG LIGHTER 4.) MUST EXTEND WATER HTR FLU VENT 1'-0" ABOVE COOLER. 5.) PT DRAIN MUST HAVE GRAVITY FLOW AND NO FLEX LINE OR DRAIN VALVE. 6.) MUST USE (3) SHEET METAL SCREWS @ EACH JOINT & VENT CONNECTOR FOR WATER HTR FLU VENT 7.) RE TEST SYSTEMS. |
| 10/24/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) WATER HTR FLU VENT, P & T DRAIN OK NOTE: P & T DRAIN WAS EXSISTING WITH DRAIN VALVE. 4.) FURANCE FLU VENT OK 5.) OK TO BACKFILL TRENCH. 6.) U.C.C HAS BEEN PLACED @ METER LOCATION. 7.) NOTE: PLBG. CONTRACTOR MSUT SEAL & SCREW DOWN FLASHING ON ROOF AND CONNECT DRYER FLEX. |