Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 10/30/2001 |
PLUMBING - GAS RECONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 10/22/2001 |
PLUMBING - GAS RECONNECT |
|
Partial Approval |
IVRS - Inspection 0000*PLUMBING GAS RECONNECT. SYSTEM PRESSURIZED TO 10 P.S.I. BY CONTRACTOR A.M. AT 11:30 AM PRESSURE GUAGE WAS DOWN TO6 P.S.I. SMALL LEAK IN SYSTEM. LOCATE & REPAIR. |
| 10/19/2001 |
PLUMBING - GAS RECONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) REMOVE FLEX LINES FROM APPLIANCE INSTALL PLUGS IN APPLIANCE END OF FLEX LINES. RE-INFLATE. USE A GUAGE THAT IS GRADUATED IN 1/10 TH PSI INCREMENTS. SOAP TEST ALL JOINTS WHEN PRESSURIZED. |