Inspection History: PLUMBING - GAS RECONNECT

Permit Number - T01PL02074

Inspection Description - PLUMBING - GAS RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2001 PLUMBING - GAS RECONNECT Approved IVRS - Inspection 0000*
10/22/2001 PLUMBING - GAS RECONNECT Partial Approval IVRS - Inspection 0000*PLUMBING GAS RECONNECT. SYSTEM PRESSURIZED TO 10 P.S.I. BY CONTRACTOR A.M. AT 11:30 AM PRESSURE GUAGE WAS DOWN TO6 P.S.I. SMALL LEAK IN SYSTEM. LOCATE & REPAIR.
10/19/2001 PLUMBING - GAS RECONNECT Partial Approval IVRS - Inspection 0000*1.) REMOVE FLEX LINES FROM APPLIANCE INSTALL PLUGS IN APPLIANCE END OF FLEX LINES. RE-INFLATE. USE A GUAGE THAT IS GRADUATED IN 1/10 TH PSI INCREMENTS. SOAP TEST ALL JOINTS WHEN PRESSURIZED.