Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 12/27/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
|
| 11/15/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*GAS PRESSURE TEST 1.) NO PRESSURE TEST 2.) WRAP ALL UNDERGROUND FITTINGS AND MARRED PIPE 3.) ALL PIPING LESS THAN 6" ABOVE GRADE MUST BE SCOTCHCOAT. 4.) ALL PIPING MUST BE SUPPORTED. 5.) NO T&P DRIAN ON WATER HEATER. 6.) WATER HEATER ENCLOSURE NOT SUPPORTED 7.) ALL VALVES MUST BE AGA OR CSA APPROVED. 8.) FLEX CONNECTOR MAY NOT PASS THRU PARTITION 7.) PROVIDE CLEAN SOILS FOR BACKFILL. |
| 11/06/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Partial Approval |
IVRS - Inspection 0000* |
| 10/19/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
DENIED NEED 10 PSI FOR 15 MIN. |