Permit: T01PL01567

Parcel: 133131100


Addresses:

7821 E ADAMS ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/11/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 2.) WATER HTR FLU VENT, P & T DRAIN IS OK 4.) FURNACE FLU VENT IS OK 5.) ALL CORRECTION HAVE BEEN AMDE 6.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
08/09/2001 PLUMBING - FINAL Denied IVRS - Inspection 0333*1.) MUST REMOVE FLEX LINE IN P & T DRAIN AND RUN 3/4" ALL THE WAY TO DAYLIGHT 2.) MUST SCREW DOWN WITH (3) SHEET METAL SCREWS PER JOINT ON ALL FLU VENTS & VENT CONNECTOR. 3.) MUST STRAP DOWN 3/4" DROP IN FURNANCE RM.