Permit: T01PL01534

Parcel: 11203373A


Addresses:

3524 N TREAT AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/04/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVE ARE OK 3.) WATER HTR FLU VENT, P&T DRIAN OK 4.) FURANCE FLU VENT IS OK 5.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
08/02/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) MUST PROVIDE AIR PRESSURE TEST 10LBS MIN @ TIME OF INSPECTION 2.) MUST REMOVE UNION @ METER LOCATION AND IN FURNACE RM.3.) MUST USE ADHESIVE TAPE PRIMER ON ALL JOINTS AND WRENCH MARKS THEN APPLY 10 MIL TAPE 4.) MUST USE RIGHT & LEFT HAND NIPPLE IN LEU OF UNIONS. 5.) MUST REMOVE OLD SHUT OFF VALVE FOR FURNACE AND REPLACE WITH AGA SHUT OFF VALVE. 6.) MUST EXTEND HARD 1/2" PIPE THROUGH CABINET WALL FOR RANGE THEN INSTALL VALVE AND FLEX.