Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 08/04/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVE ARE OK 3.) WATER HTR FLU VENT, P&T DRIAN OK 4.) FURANCE FLU VENT IS OK 5.) U.C.C. HAS BEEN PLACED @ METER LOCATION. |
| 08/02/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*1.) MUST PROVIDE AIR PRESSURE TEST 10LBS MIN @ TIME OF INSPECTION 2.) MUST REMOVE UNION @ METER LOCATION AND IN FURNACE RM.3.) MUST USE ADHESIVE TAPE PRIMER ON ALL JOINTS AND WRENCH MARKS THEN APPLY 10 MIL TAPE 4.) MUST USE RIGHT & LEFT HAND NIPPLE IN LEU OF UNIONS. 5.) MUST REMOVE OLD SHUT OFF VALVE FOR FURNACE AND REPLACE WITH AGA SHUT OFF VALVE. 6.) MUST EXTEND HARD 1/2" PIPE THROUGH CABINET WALL FOR RANGE THEN INSTALL VALVE AND FLEX. |