Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01PL01507
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/04/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) OVERHEAD GAS SYSTEM IS OK 3.) GAS SHUT OFF VALVES IS OK 4.) WATER HTR FLU VENT, P & T DRAIN IS OK 5.) GAS PACK IS ON ROOF. 6.) U.C.C. HAS BEEN PLACED @ METER LOCATION. | |
07/31/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) MUST REMOVE ALL UNION IN LINE. YOU MAY USE A RIGHT & LEFT HAND NIPPLE IN LOW OF UNION.2.) MUST HAVE 1" GAS PIPE UP TO 1ST TEE FOR AC UNITS ON ROOF.3.) MUST REMOVE P&T FLEX LINE AND RUN FULL SIZE 3/4 DRAIN TO EXSISTING P&T DRAIN. 4.) MUST SCREW DOWN ALL FLU VENT JOINTS AND VENT CONNECTOR WITH 3 SCREWS 5.) RE-TEST. |