Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/04/2001 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) OVERHEAD GAS SYSTEM IS OK 3.) GAS SHUT OFF VALVES IS OK 4.) WATER HTR FLU VENT, P & T DRAIN IS OK 5.) GAS PACK IS ON ROOF. 6.) U.C.C. HAS BEEN PLACED @ METER LOCATION. |
| 07/31/2001 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) MUST REMOVE ALL UNION IN LINE. YOU MAY USE A RIGHT & LEFT HAND NIPPLE IN LOW OF UNION.2.) MUST HAVE 1" GAS PIPE UP TO 1ST TEE FOR AC UNITS ON ROOF.3.) MUST REMOVE P&T FLEX LINE AND RUN FULL SIZE 3/4 DRAIN TO EXSISTING P&T DRAIN. 4.) MUST SCREW DOWN ALL FLU VENT JOINTS AND VENT CONNECTOR WITH 3 SCREWS 5.) RE-TEST. |