Permit: T01PL01504

Parcel: 128051610


Addresses:

5610 E 20TH ST

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/16/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PLUMBER NEEDS TO INSTALL A PRESSURE REDUCTIN. VALVE, WITH A DUMP, SET AT 125#, ON THE COLD WATER SYSTEM AS DESCRIBED IN THE CITY HANDOUT. VACUUM BREAKER.
08/16/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) RE-INSPECTION 2:15PM 8/16/01 2.) PLUMBING INSTALLED WATT M3 174A 3/4" 125LB PRESSURE RELIEF VALVE. 3.) OK FOR GAS 4.) LEFT UCC AT METER.
08/14/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) WATER HEATER T $ P DRAIN DUMPED INTO SMITTY PAN OK 2.) INSTALL PRESSURE REDUCING VALVE SET AT #125 ON THE COLD WATER SYSTEM TO DUMP OUTSIDE.
08/06/2001 PLUMBING - FINAL Denied IVRS - Inspection 0000*PAY ONE RE INSPECTION FEE BEOFRE NEXT INSPECTION .
08/04/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) PRESSURE TEST ONLY OK 2.) P.F RELIEF DISCHARGE CANNOT BE TRAPED .