Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/30/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) WATER HTR FLU VENT OK 4.) FURANCE FLU VENT OK 5.) ALL CORRECTIONS HAVE BEEN MADE 6.) U.C.C. HAS BEEN PLACED @ METER. |
| 07/27/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) MUST PROVIDE A AGA OR CSA APPROVED GAS SHUT OFF VALVE BEFORE THE UNION @ WEST SIDE OF HOUSE. 2.) MUST APPLY TAPE PRIMER ON PIPE & JOINTS TO BE WRAPPED UNTIL TACKY THEN APPLY 10 MIL TAPE. 3.) MUST SCREW DOWN ALL JOINTS FOR FLU VENT (3) SCREWS EACH @ WATER HTR, & FURNACE & VENT COLLAR 4.) MUST PROVIDE AGA OK CSA GAS SHUT OF VALVES FOR WATER HTR & FURANCE. 5.) MUST REMOVE FLEX LINE ON P & T DRAIN AND REPLACE P & T VALVE. 6.) RE TEST SYSTEM 7.) MUST HARD PIPE OUT OF FURNACE HOUSEING THEN FLEX LINE. |