Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/26/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) WATER HTR #2 P & T DRAIN & VALVE, FLU VENT OK 4.) FURNACES FLU VENT OK 5.) NOTE: WATER HTR #1 P & T DRAIN WAS EXSISTING AND GOES UP THRU ROOF 6.) O.C.C. HAS BEEN PLACED @ METER LOCATION. |
| 07/25/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) WATER HTR #1 DRAIN CAN NO LONGER GO UP THRU ROOF WITH DRAIN. P & T DRAIN MUST GO TO DAY LIGHT WITH GRAVITY FLOW OR INTO A APPROVED RECEPTOR. IF THIS CAN NOT BE ACCOMPLISHED THEN YOU MAY RESORT TO NEW ALTERNATE INSTALLATION SEE DETAIL SHEET. 2.) REMOVE UNION FOR SUPPLY FOR WATER HTR #2 @ SOUTH SIDE OF HOUSE THIS UNION DOSE NOT NEED TO BE THERE. 3.) MUST SCREW DOWN FLU VENTS FOR ALL GAS APPLIANCES WITH (3) SCREWS PER JOINT AND VENT CONNECTOR. 4.) RE TEST SYSTEM. 5.) MUST VERIFY THAT PEOPLE FOR WATER HTR #2 IS LONG ENOUGH FOR WATER HTR. |