Permit: T01PL01458

Parcel: 127100440


Addresses:

701 N ROOK AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/24/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) WATER HTR FLU VENT, P&T DRAIN IS OK 4.) FURANCE FLU VENT IS OK 5.) ALL CORRECTIONS HAVE BEEN MADE 6.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
07/23/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) ENTIRE GAS LINE SYSTEM HAS BEEN PAINTED YOU CAN NOT PAINT GAS LINE UNTIL THE SYSTEM HAS BEEN INSPECTED IN ORDER TO IDENTIFY APPROVED MARKINGS ON PIPE SEE SECTION 301.1.2. 94 UPC. 2.) MUST SCREW DOWN SINGLE WALL FLU VENT FOR WATER HTR (3) SCREWS @ EACH JOINT AND VENT CONNECTOR (3. MUST HAVE APPROVED AGA GAS SHUT OFF VALVE FOR RANGE. 4.) MUST USE APPROVED MATERIAL FOR P&T DRAIN @ WATER HTR.5.) MUST STRAP 1/2" DROP FOR FURNACE AND ADD A BLOCK & STRAP WHERE RUN GOSES FOR RANGE & WATER HTR 6.) GAS PRESSURE TEST IS OK.