Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01PL01411
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*1.) SEPTIC TANK IS IN REALITY A CESSPOOL AND OVERFLOW OK TO FILL 2.) ALL CORRECTION MADE OK 3.) OK TO BACKFILL | |
| 07/18/2001 | PLUMBING - ROUGH, SOIL | Denied | 1.REGRADE 3" ABS BLDG SEWER TO ALLOW 1/4" PER FOOT FALL FOR ENTIRE LENGTH OF SEWER 2.) BATHROOM PIPING TO BLDG DRAIN NOT APPROVED A) PIPING UNDERSIZED WATER CLOSET NOT ALLOWED ON 2" PIPE B.) ABS MUST HAVE AT LEAST 12" COVER 3.) NO VENT AT LAVATORY. 3.) KITCHEN PIPING NOT APPROVED A) ABS TO HAVE A MINIMUM 12" OF COVER 4.) PUMP SEPTIC, BREAK OUT BOTTOM, AND CALL FOR INSPECTION BEFORE FILLING IN. |