Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01PL01411

Parcel: 120085380


Addresses:

342 W KENTUCKY ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T01PL01411

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) SEPTIC TANK IS IN REALITY A CESSPOOL AND OVERFLOW OK TO FILL 2.) ALL CORRECTION MADE OK 3.) OK TO BACKFILL
07/18/2001 PLUMBING - ROUGH, SOIL Denied 1.REGRADE 3" ABS BLDG SEWER TO ALLOW 1/4" PER FOOT FALL FOR ENTIRE LENGTH OF SEWER 2.) BATHROOM PIPING TO BLDG DRAIN NOT APPROVED A) PIPING UNDERSIZED WATER CLOSET NOT ALLOWED ON 2" PIPE B.) ABS MUST HAVE AT LEAST 12" COVER 3.) NO VENT AT LAVATORY. 3.) KITCHEN PIPING NOT APPROVED A) ABS TO HAVE A MINIMUM 12" OF COVER 4.) PUMP SEPTIC, BREAK OUT BOTTOM, AND CALL FOR INSPECTION BEFORE FILLING IN.