Permit: T01PL01367

Parcel: 132101740

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
07/17/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
07/15/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) SYSTEM WILL NOT HOLD 10LB AIR TEST. 2.) REPAIR LEAK TEST TO 10LBS AND RECALL FOR INSPECTION.
07/12/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) WHERE PIPING MEETS CONNECTION SHALL BE MADE WITH A RIGHT LEFT NIPPLE AND COUPLING 2.) ALL PIPE BELOW GRADE SHALL BE SCOTCHCOAT PRIME AND WRAP JOINTS 3.) ALL VALVES TO BE AGA OR CSA APPROVED. 4.) EXTEND T&P RELIEF TO WITHIN 6" OF GRADE AIR TEST TO 10LBS