Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01PL01343

Parcel: 120083640


Addresses:

237 W MISSOURI ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/15/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) AIR TEST OK 3.) VALVES AND FLEXES OK 4.) OK FOR GAS 5.) OK TO COVER.
07/05/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) WHERE PIPING MEETS, THE CONNECTION SHALL BE WITH A RIGHT LEFT NIPPLE AND COUPLING. A GROUND JOINT UNION MAY BE USED IN AN EXPSOED EXTERIOR LOCATION WHEN PROCEEDED BY A BUILDING SHUT OFF VALVE. 2.) ALL NEW PIPING INSTALLED BELOW GRADE TO 6" ABOVE GRADE MUST BE SCOTCHCOAT.3.) ALL FITTINGS AND MARRED PIPE TO BE PRIMED AND TAPED 4.) T&P RELIEF VALVE IN OPERABLE. 5.) TANK APPEARS TO BE LEAKING.