Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/15/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) AIR TEST OK 3.) VALVES AND FLEXES OK 4.) OK FOR GAS 5.) OK TO COVER. |
| 07/05/2001 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) WHERE PIPING MEETS, THE CONNECTION SHALL BE WITH A RIGHT LEFT NIPPLE AND COUPLING. A GROUND JOINT UNION MAY BE USED IN AN EXPSOED EXTERIOR LOCATION WHEN PROCEEDED BY A BUILDING SHUT OFF VALVE. 2.) ALL NEW PIPING INSTALLED BELOW GRADE TO 6" ABOVE GRADE MUST BE SCOTCHCOAT.3.) ALL FITTINGS AND MARRED PIPE TO BE PRIMED AND TAPED 4.) T&P RELIEF VALVE IN OPERABLE. 5.) TANK APPEARS TO BE LEAKING. |