Permit: T01PL01298

Parcel: 110140170

Inspection Status: Denied

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T01PL01298

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Denied

Date Description Inspector Results Comments
07/05/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*YOU CAN NOT REDUCE GAS LINES FROM 1" THIS LINE & GAS VALUE MUST E1" 2.) RETEST SYSTEM TO 10IBS PRESSURE MININUM.
07/05/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALUES OK 3.) WATER HTR FLU VENT P&T DRAIN OK 4.) FURANCE IS GAS PACK ON ROOF OK 5.) OK TO BACKFILL TRENCH 6.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
06/29/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) MUST USE AGA OR CSA APPROVED GAS SHUT OFF VALVE @ BLDG OR REPLACE WITH A RIGHT & LEFT HAND NIPPLE. 2.) WATER HTR P&T DRAIN MATERIAL CAN NOT BE BLK IRON PIPE OR COPPER OR CPVC MAY BE USED 3._ MUST TAPE PRIMER ALL JOINTS IN GAS LINE UNDERGROUND THEN APPLY TAPE WEAP. 4.) DISSREGARD NOTE #3
06/27/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*