Permit: T01PL01291

Parcel: 11207216A


Addresses:

2617 N FORGEUS AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/16/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS HAVE BEEN MADE 2.) U.C.C. HAS BEEN PLACED @ METER LOCATION.
07/30/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) GAS PRESSURE TEST IS OK 2.) OK TO BACKFILL TRENCH 3.) WATER HTR P&T DRAIN MUST EXTEND TO 6" A.F.F. 4.) MUST REMOVE SINGLE WALL FLU VENT AND REPLACE WITH DBL WALL B-VENT & CAP 5.) MUST SCREW DOWN ALL FLU VENT JOINTS (3) SCREWS EACH AND @ VENT CONNECTOR 6.) MUST HAVE AGA SHUT OFF VALVE FOR RANGE.