Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 09/19/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK NO SEPTIC TANK, CESSPOOL. PUMP AND FILL CESSPOOL. 2.) OK TO CONNECT TO HCS/CONNECTION WATER TEST OK OK TO BACKFILL-HOME OWNER TO INSURE CLEAN FILL IS USED AROUND SEWER PIPE. |
| 09/18/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
IVRS - Inspection 0000*1.) USE APPROVED SHIELDED COUPLING FOR TRANSITION FROM ABS TO STEEL PIPE. 2.) WATER TEST SEWER FROM LOWEST TO HIGHEST POINT AND RECALL FOR INSPECTION. |
| 09/06/2001 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*1.) NO ADDRESS POSTED. 2.) NO PERMIT ON SITE 3.) SEVERAL SECTIONS BACKPITCHED. 4.) PIPE TO BE LAID ON A FIRM BED ( NO BRIDGING) SHADED WITH CLEAN FILL 5.) CHANGES OF DIRECTION FROM VERTICAL TO HORIZIONTAL TO BE A SWEEP 6.) ABS NOT APPROVED IN EXTERIOR EXPOSED LOCATION 7.) NEED TO SEE SEPTIC TANK WITH LID BROKEN AND TANK PUMPED THEN, AFTER THAT INSPECTION I NEED TO SEE THE BOTTOM OF THE TANK BROKEN, AND THE APPROVED FILL FOR FILLING THE TANK 8.) NATIVE SOILS FOR SEWER TOO ROCKY, WILL CLEAN FILL FOR SHADING. |