Permit: T01PL01177

Parcel: 118036550


Addresses:

2170 S CERRO DR


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01PL01177

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/25/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK
2.) VALUES AND FLEXES OK 3.) OK FOR GAS
06/21/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1)REVIEWED APPROVED DRAWING GAS PIPING OK.2)PRESSURE TEST OK.
3)EXISTING GAS VALUE AT WATER HEATER NOT APPROVED.4)NO VAULE OR FLEX AT DRYER OR STOVE.I NEED TO SEE APPROVED CONNECTORS.
06/12/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1)CSST AND BLACK IRON PIPE ARE SIZED BY DIFFERENT CRITERIA.I QUESTION THE INTERMINGLING OF THESE MATERIAL TYPES, AND WOULD REQUIRE DOCUMENTATION SUPPORTINF THIS PRACTICE, AS WELL AS AN APPROVED GAS ISOMETRIC SHOWING MATERIAL AND SIZE.2)ALL VALVES AND FLEXES MUST BE APPROVED TYPE INCLUDING WATER HEATER AND STOVE.