Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OK TO BACKFILL. | |
| 07/22/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) UNABLE TO SEE CONNECTIONS AT METER SEE NOTE #2 6/12/01 | |
| 06/17/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* | |
| 06/15/2001 | PLUMBING - FINAL | Denied | 1.) PLEASE SEE NOTE #1 ABOVE THIS IS THE THIRD INSPECTION FOR THIS WATER LINE. 2.)CONTRACTOR TO PAY RE-INSPECTION FEE |
|
| 06/14/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)EXPOSE ALL PIPE AND FITTINGS BETWEEN METER AND HOUSE. | |
| 06/12/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)PVC MUST HAVE A MINIMUM OF 12" OF COVER.2)EXPOSE ALL FITTINGS AND CONNECTIONS BETWEEN THE METER AND THE HOUSE.3)STRAP VERTICAL PIPING BEHIND T AND S VALVE SO IT WON'T BANG IN THE WALL.4)STRAP COLD LINE BEHIND AW. BOX SO IT WON'T BANG IN THE WALL.5)UNKINK HOSE AT W.C, CONNECTION-INHIBITING FLOW TO TANK. |