Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/11/2001 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*TEST OK CONNECTIONS HAVE BEEN MADE.PLEASE PROVIDE STORM COLLER AS REQUIRED BY LISTING. |
| 06/07/2001 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1)OVAL B VENT INSTALLED ON WALL HEATER IS INSTALLED UPSIDE DOWN.RE INSTALL VENT THE RIGHT WAY.2)VENT CAP IS SMASHED ON TOP-REPLACE OR REPAIR AS NEEDED.3)PROVIDE MIN. 1" CLEARANCE AROUND B VENT THRU ROOF FROM COMBUSTIBLES.CORRECT AND RECALL FOR FINAL INSPECTION. |
| 06/07/2001 |
PLUMBING - FINAL |
|
Partial Approval |
TEST OK ON NEW GAS LINE.WILL NEED MECH INSPECTION TO CHECK OUT VENT AT WALL HEATER.IF VENT IS OK PLEASE PROVIDE GAS CARD. |
| 05/30/2001 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |