Permit: T01PL00717

Parcel: 11106058A

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T01PL00717

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
04/13/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) FLU VENT FOR WATER HEATER AND FURNACE MUST TERMINATE 1'-0" ABOVE COOLER WHEN FLU VENT IS LOCATED WITHIN 10' OF COOLER. 2) PA AND T DRAIN MUST NOT TURN DOWN ONTO ROOF. THIS DRAIN MUST SPRAY UP TO SKY FOR COOLING 3) FURNACE FLEX CONNECTOR CAN NOT GO THRU APPLIANCE HOUSING THIS MUST BE HARD PIPED THRU HOUSING THEN FLEX CONNECTOR 4) P AND T DRAIN HAS KINK IN LINE
04/06/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) WATER HEATER P AND T DRAIN MUST GO TO DAYLIGHT 2) WATER HEATER FLUE VENT NOT INSTALLED PROPERLY. MUST HAVE 3 SHEET METAL SCREWS AT COLLAR AND ALL JOINTS