Permit: T01PL00713

Parcel: 120077050


Addresses:

526 W PALMDALE ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/27/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
07/25/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) A NO-HUB BAND IS NOT APPROVED AS A TRANSITION FITTING FROM ABS TO CAST IRON. 2.) THE POINT OF VENT FOR A FIXTURE SHALL NOT BE BELOW THE WEIR OF THE TRAP.
07/19/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) KITCHEN SINK THE VENT SHALL NOT CONNECT BELOW THE WEIR OF THE TRAP A SANTEE CANNOT LAY ON ITS BACK THE TRAP SHALL BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. 2.) VENT FOR WATER CLOSET COMBO IN BACKWARDS 3.) NO VENT RUN FOR LAVATORY 4.) ISOLATE WATER LINES COPPER CANNOT TOUCH COPPER. 5.) PROTECT EXTERIOR COPPER LINES FROM FREEZING 6.) INSTALL VACUUM BREAKERS ON HOSE BIBBS 7.) VERIFY GAVANIZED NOT CONNECTED DIRECTLY TO COPPER 8.) TAKE OUT PERMIT FOR WATER HEATER.