Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01PL00705

Parcel: 122122060


Addresses:

4451 E FAIRMOUNT ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/12/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000* FLEX CONNECTOR TO WASTE HEATER CANNOT PENETRATE THE ENCLOSURE. USE RIGID PIPE THRU ENCLOSURE CORRECT AND RECALL FOR FINAL
04/02/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999* 1) MUST REMOVE THREAD PROTECTOR IN LINE AND REPLACE WITH APPROVED COUPLING 2) RANGE HAS 3/4" INLET THEN GAS LINE TO THIS APPLIANCE MUST BE 3/4" 3) WATER HEATER MUST HAVE AN ENCLOSURE 4) MUST SCREW DOWN FLU VENT AT ALL JOINTS AND COLLAR 5) RETEST SYSTEM