Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 04/12/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* FLEX CONNECTOR TO WASTE HEATER CANNOT PENETRATE THE ENCLOSURE. USE RIGID PIPE THRU ENCLOSURE CORRECT AND RECALL FOR FINAL |
| 04/02/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999* 1) MUST REMOVE THREAD PROTECTOR IN LINE AND REPLACE WITH APPROVED COUPLING 2) RANGE HAS 3/4" INLET THEN GAS LINE TO THIS APPLIANCE MUST BE 3/4" 3) WATER HEATER MUST HAVE AN ENCLOSURE 4) MUST SCREW DOWN FLU VENT AT ALL JOINTS AND COLLAR 5) RETEST SYSTEM |