Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 04/23/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 04/16/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0000* PLEASE MAKE CORRECTIONS AND CALL AGAIN FOR INSP. |
| 04/11/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0340*/1. SYSTEM PRESSURE DOWN TO 5 PSI AT TIME OF INSP. |
| 03/29/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999* 1) WHEN GAS METER IS LOCKED YOU MUST BRING EXSISTING GAS LINE TO CURRENT CODE 2) MUST REMOVE UNIONS IN LINE AND REPLACE WITH RIGHT AND LEFT HAND NIPPLE AND COUPLINGS 3) WATER HEATER FLU VENT JOINTS MUST HAVE SHEET METAL SCREWS AT ALL JOINTS AND COLLAR 4) WATER HEATER P AND T DRAIN MUST GO TO DAYLIGHT |