Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2001 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999* | |
| 05/03/2001 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* 1) NO MARKING ON SADDLE ON JOB SITE. LETTER ON JOB REQUESTING USE OF DFW SADDLE. NOTHING IN INFO ABOUT DIP I NEED A LISTED SADDLE FOR DIP PIPE. INFO TO GO THRU PLAN CHECK AND STAMPED. 2) CODE VIOLATION ON CO AT BACK WATER VALVE REMOVE SAN TEC AND INSTALL WYE AND 1/8" BEND OR COMBO | |
| 04/30/2001 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* 1) PLEASE PROVIDE DETAIL ON HCS FROM DIP BY ENGINEER 2) PLEASE SEE STANDARD DETAIL 401 HCS MACHINE CUT 45 DEGREES ABOVE CENTER LINE OF PIPE 3) PROVIDE CO ON EACH SIDE OF BACK WATER VALVE/ PIT REQUIRED AS PER SEC 710.6 |
|
| 04/17/2001 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* | |
| 04/13/2001 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | PLEASE NOTE: 1513 E. AEELAIDE DR. CALL PIMA CO. FOR MANHOLE. CALL COT FOR HSC & SITE SEWER. |