Permit: T01PL00577

Parcel: 13811029B


Addresses:

6214 S FONTANA AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/16/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
03/13/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999* 1) THERE IS EVIDENCE(SOFT SOIL) THAT THE GASLINE HAS BEEN REPLACED FROM THE METER TO THE HOUSE AND THEN COVERED. ALL UNDER GROUND PIPING TO 6" ABOVE GRADE MUST BE SCOTCH COAT WITH ALL FITTINGS AND MARRIED PIPE WRAPPED WITH 10MIL TAPE.
2) WATER HEATER IS NOT RATED FOR OUTDOOR USE 3) NOT PART OF THIS INSP., BUT I OBSERVED THAT THERE IS A HEALTH HAZARD AT THE KITCHEN SINK DRAIN. PLEASE OBTAIN A PERMIT AND CORRECT THE NUMEROUS VIOLATIONS IN THIS AREA. 4) WHEN READY, CALL IN ALL INSP.