Permit: T01PL00523

Parcel: 110090740


Addresses:

5407 E GLENN ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS RECONNECT

Date Description Inspector Results Comments
03/09/2001 PLUMBING - GAS RECONNECT Approved IVRS - Inspection 0000*
03/08/2001 PLUMBING - GAS RECONNECT Cancelled IVRS - Ri canceled
03/06/2001 PLUMBING - GAS RECONNECT Denied IVRS - Inspection 0999* 1) MUST PROVIDE AIR PRESSURE TEST ON SYSTEM 10# MINIMUM 2) MUST SCREW DOWN ALL JOINTS AND COLLAR ON FLU VENTS WITH SHEET METAL SCREWS 3) BRICKS ARE NOT APPROVED MATERIALS FOR BRACING GASLINE. MUST USE APPROVED STRAPS ON GAS LINE.
4) MUST HAVE A LICENCED PLMB. CONTRACTOR TO DO ANY WORK ON GAS SYSTEM FOR RENTAL PROPERTY. THIS IS A STATE REQUIREMENT.
5) MUST HAVE HARD PIPE GAS LINE OUT OF HOUSING OF APPLIANCE AT FURNACE THEN CONNECT FLEX LINE SEE SEC. 1212.0 94 UPC SUB NOTE #2