Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2001 | PLUMBING - GAS RECONNECT | Approved | IVRS - Inspection 0000* | |
| 03/08/2001 | PLUMBING - GAS RECONNECT | Cancelled | IVRS - Ri canceled | |
| 03/06/2001 | PLUMBING - GAS RECONNECT | Denied | IVRS - Inspection 0999* 1) MUST PROVIDE AIR PRESSURE TEST ON SYSTEM 10# MINIMUM 2) MUST SCREW DOWN ALL JOINTS AND COLLAR ON FLU VENTS WITH SHEET METAL SCREWS 3) BRICKS ARE NOT APPROVED MATERIALS FOR BRACING GASLINE. MUST USE APPROVED STRAPS ON GAS LINE. 4) MUST HAVE A LICENCED PLMB. CONTRACTOR TO DO ANY WORK ON GAS SYSTEM FOR RENTAL PROPERTY. THIS IS A STATE REQUIREMENT. 5) MUST HAVE HARD PIPE GAS LINE OUT OF HOUSING OF APPLIANCE AT FURNACE THEN CONNECT FLEX LINE SEE SEC. 1212.0 94 UPC SUB NOTE #2 |