Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/12/2001 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* PLEASE PROVIDE APPROVED TYPE VENT CAP FOR DOUBLE WALLS AND CALL AGAIN. |
| 03/07/2001 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* 1) CODE VIOLATION AT WATER HEATER VENT.PLEASE PROVIDE DOUBLE WALL VENT 1'0" ABOVE ROOF. PROVIDE 1" CLEARANCE ON DOUBLE WALL. PLEASE SEE SEC 516.1 94 UPC FOR LENGTH PITCH AND CLEARANCE. I THINK YOU NEED TO HIRE A PLUMBER |
| 03/06/2001 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* NEED VENT INSTALLED PER CODE AND NEED DRAIN PIPING INSTALLED ON SAFTY VALVE |