Permit: T01PL00475

Parcel: 122171670


Addresses:

3315 E CAMDEN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/27/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
03/19/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) WATER LINES UNDERGROUND MUST BE MINIMUM 12" DEEP. SEE SEC. 609.1 94 UPC 2) MUST HAVE PROPER TRANSITION FROM DISSIMULAR METALS. COPPERR IS CONNECTED TO GALVANIZED TEE. SEE SEC. 316.2.1 94 UPC 3) MUST PAY RE INSP. FEE BEFORE NEXT INSP.
03/14/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) MUST EXPOSE ALL COPPER UNDERGROUND FOR INSP. 2) MUST INSULATE EXPOSED COPPER LINES