Permit: T01PL00263

Parcel: 133323860


Addresses:

9161 E 8TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01PL00263

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
GAS PRESSURE TEST OK
GAS SHUT OFF VLAVES OK
WATER HEATER FLU VENT OK P&T DRAIN OK
ALL CORRECTIONS HAVE BEEN MADE
02/01/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*
MUST HAVE AGA SHUT OFF VALVE BEFORE UNION AT BLDG SERVICE OR REMOVE UNION AND REPLACE WITH RIGHT AND LEFT HAND NIPPLE, SEE SECTION 1211.10 94 UPC
SHUT OFF VALVE FOR GAS PACK ON ROOF MUST BE WITHIN 3'-0" OF APPLIANCE SEE SECTION 1211.15 94 UPC
WATER HEATER FLU VENT MUST TERMINATE 1'-0" ABOVE COOLER WHEN LOCATED WITHIN 10'-0" FROM COOLER
01/31/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*
NOBODY HOME
PLEASE CALL BACK IN WHEN AN ADULT CAN BE HOME TO ASSIST THE INSPECTOR