Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T01PL00133
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2001 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000* GAS PRESSURE TEST OK GAS SHUT OFF VALVES OK WATER HEATER FLU VENT, P&T DRAIN OK FURNACE FLU ENT OK U.C.C. HAS BEEN ISSUED ALL CORRECTIONS HAVE BEEN MADE |
|
01/22/2001 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* I MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENT FROM COMBUSTIONABLE MATERIAL WATER HEATER FLU VENT MUST BE 1'-0" ABOVE COOLER IF VENT IS WITHIN 10'-0" |