Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* GAS PRESSURE TEST OK GAS SHUT OFF VALVES OK WATER HEATER P&T DRAIN, FLU VENT OK FURNACE FLU VENT OK ALL CORRECTIONS HAVE BEEN MADE |
|
| 01/19/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1. GAS LINE FROM METER TO HOUSE SERVICE IS UNDERSIZED THIS LINE MUST BE MIN, 1" SEE TABLE 12-3 94 UPC 2. MUST SCREW DOWN SINGLE WALL FLU VENT WITH (3) SHEET METAL SCREWS AT WATER HEATER COLLAR AND ALL FLU VENT JOINTS 3. WATER HEATER P&T DRAIN MUST HAVE DRAIN VALVE INSTALLED IN LINE, THERE CAN BE NO TRAPED WATER 4. SHUT OFF VLAVE FOR DRYER MUST BE WITHIN 3'-0" FROM APPLIANCE CONNECTION SEE SECTION 1211.15 94 UPC 5. GAS SYSTEM MUST HAVE MIN 10 LBS OF PRESSURE AT TIME OF INSPECTION |
|
| 01/16/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* I MUST HAVE ACCESS TO ALL GAS APPLIANCES PLEASE CALL 791-5550 TO MAKE A APPOINTMENT CAN NOT HAVE ANY UNIONS IN LINE OR PROVIDE APPROVED GAS SHUT OFF VALVE BEFORE NION MUST USE APPROVED COUPLINGS ON GAS LINE, THREAD PROTECTORS ARE NOT APPROVED COUPLING NOTE: MUST HAVE A LICENSE PLUMBING CONTRACTOR TO WORK ON GAS SYSTEM IF THIS IS A RENTAL PROPERLY, (STATE REQUIREMENT) |