Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/11/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
PRESSURE TEST 10#
PIPING OK
OK TO COVER
APPPLIANCES OK
OK FOR GAS
01/10/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
GAS PIPE MUST BE A MINIMUM 12" BFG
WHERE DIVERGENT PIPING MEETS, THE CONNECTION SHALL BE MADE WITH A RIGHT-LEFT HAND COUPLING AND NIPPLE, A UNION MAY BE USED IN AN EXTERIOR ACCESSIBLE LOCATION ONLY WHEN PRECEEDED BY A BLDG SHUT OFF VALVE
UNABLE TO VISUALLY INSPECT VALVE FOR FURNACE MUST BE AGA APPROVED
NO COMBUSTION REFIEF IN WATER HEATER CLOSET
NO DRAIN ON T&P REFIEF DRAIN LINE