Permit: T01PL00004

Parcel: 112041390

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/08/2001 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
ALL CORRECTIONS HAVE BEEN MADE
01/04/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
MUST HAVE LICENSE PLDG CONTRACTOR TO WORK ON GAS LINE ON RENTAL PROP
MUST BE ABLE TO VERIFY GAS LINE MATERIAL
P&T DRAIN HAS BACK PITCH AND IS LEVEL ON FLOOR
P&T DRAIN MUST BE SECURED WITH APPROVED STRAPS
NO BLK PIPE ALLOWED ON P&T DRAIN
MUST PAY REINSPECTION FEE BEFORE NEXT INSPECTION
01/03/2001 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
GAS LINE HAS BEEN PAINTED, I CAN NOT VERIFY APPROVED MARKINGS ON PIPE. SEE SECTION 301.1.2 94 UPC
WATER HEATER P & T DRAIN MUST GO TO DAYLIGHT
WATER HEATER P&T DRAIN LINE CAN HAVE 12" MAX OF FLEX LINE
MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENT FOR WATER HEATER