Permit: T01MH00523

Parcel: 10706002D

Inspection Status: Approved

Inspection History: MOBILE HOME PLUMBING

Permit Number - T01MH00523

Inspection Description - MOBILE HOME PLUMBING

Inspection Status - Approved

Date Description Inspector Results Comments
12/14/2001 MOBILE HOME PLUMBING Approved
11/20/2001 MOBILE HOME PLUMBING Denied IVRS - Inspection 0999$1.) GAS PRESSURE TEST OK 2.) DWV PIPING REDUCING 2" TO 1 1/2" AND BACK TO 2" CONSIDERED AN OBSTRUCTION. 3.) ONLY ONE FIXTURE UNIT ALLOWED ON 1 1/2" HORIZONTALLY. ALL MULTIPLE FIXTURE UNIT FIXTURES ON 1 1/2" HORIZONTALLY WILL HAVE TO BE CHANGED TO 2" 4.) NO WATER TEST ON ABS 5.) A SANTEE MAY NOT BE INSTALLED ON ITS BACK.