Inspection History Details
Inspection Status: Approved
Inspection History: MOBILE HOME PLUMBING
Permit Number - T01MH00523
Inspection Description - MOBILE HOME PLUMBING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2001 | MOBILE HOME PLUMBING | Approved | ||
11/20/2001 | MOBILE HOME PLUMBING | Denied | IVRS - Inspection 0999$1.) GAS PRESSURE TEST OK 2.) DWV PIPING REDUCING 2" TO 1 1/2" AND BACK TO 2" CONSIDERED AN OBSTRUCTION. 3.) ONLY ONE FIXTURE UNIT ALLOWED ON 1 1/2" HORIZONTALLY. ALL MULTIPLE FIXTURE UNIT FIXTURES ON 1 1/2" HORIZONTALLY WILL HAVE TO BE CHANGED TO 2" 4.) NO WATER TEST ON ABS 5.) A SANTEE MAY NOT BE INSTALLED ON ITS BACK. |